Postdoctoral position, Lyon, France
Monte Carlo simulations of Compton camera and PGPI imaging
in hadrontherapy and nuclear medicine
The CREATIS and IPNL laboratories open in collaboration with LPSC a 2-year postdoc position in the field of simulations in biomedical imaging. The position is funded by the Labex Primes.
Scientific background
There is currently a consensus in the community of medical physicists about the need for ion-range verification in hadrontherapy. Twelve years after the original presentation of the idea, Prompt gamma (PG) detection seems a very good candidate to perform such a verification during treatments. The various approaches followed to tackle this issue can be classified in three categories [Krimmer 2017a]:
- PG imaging (PGI) with passive collimation (mutli-slit cameras [Pinto 2014, Min 2012]; knife-edge camera [Richter 2016]) and active collimation (Compton camera [Krimmer 2015, Solevi 2016]),
- Collimated scintillator with spectroscopy: Prompt Gamma Spectroscopy (PGS) [Verburg 2014],
- Scintillator with time-of-flight (TOF) measurement (with no collimation): monitoring of the ion range from the characteristics of the TOF spectrum corresponding to PG coming from the patient: either the position and the width of the spectrum (Prompt Gamma Timing (PGT) [Golnik 2014]) or the integral (Prompt Gamma Peak Integral (PGPI) [Krimmer 2016, Krimmer 2017b].
The present project deals with both Compton camera (CC) and PGPI.
Several applications of Compton cameras (CC) are actually foreseen: hadrontherapy monitoring, nuclear imaging with high energy radiotracers or Targeted Radionuclide Therapy (TRT) monitoring where most radionuclides emit high energy gammas allowing per-treatment images. CC have the potential to provide images of high-energy radiotracers with sensitivity at least 2 orders of magnitude larger than the one of conventional SPECT cameras [Han 2008, Fontana 2017] which could be a major breakthrough. A CC prototype is under development within the CLaRyS collaboration gathering several French laboratories [Krimmer 2015]. First tests of the prototype are planned by the end of 2018. . Dedicated reconstruction algorithms have been developed and quantification aspects are currently under investigation.
All these studies require input data from Monte Carlo (MC) simulations. At present, a few ad-hoc Monte Carlo simulations have been developed, either based on the Megalib package or the Geant4 platform. However, the former is not medical oriented, and the latter is difficult to use and maintained. The OpenGate collaboration already developed powerful PET and SPECT modules allowing precise simulations of clinical devices. Here, the purpose of this post-doctoral position is to develop an additional Gate module for the simulations of Compton Camera devices, both usable in nuclear medicine and hadrontherapy.
Regarding PGPI, a feasibility study has been carried out within a 2-year project (“Physique Cancer”) that led to the construction of a demonstrator with 3 detectors readout by a data acquisition board and the associated acquisition software. One of the main outcomes of this study is the sensitivity of the technique to any type of deviations: ion ranges, numbers of incident ions, patient positioning and morphological changes. Most of these parameters are strongly correlated but ion range is the most important quantity. Therefore, the combination of signals from various detectors - such as averages and ratios - has been studied, and they provide, during the treatment, information on the energy deposited in the patient (and thus the ion range) and its spatial distribution. A patent application has been submitted in July 2016 (n° FR1656378).
Tasks:
The tasks of the recruited person will be to:
- Compton camera
- Determine the main components of a CC and define a convenient parametrization
- Test by comparison with experimental data
- Investigate the possibility of variance reduction technique
- Design and implementation of a tool to make the direct connection between MC and reconstruction
- PGPI
- Optimize the detection device with treatment plans and the fast simulation tool of PG emission developed within the GATE platform [Huisman 2016]
- Assess the performances of the technique with a few relevant clinical cases.
Profile
- The candidate must hold a PhD in medical physics, physics or image processing.
- Scientific interests: Monte Carlo simulations, computer sciences (medical image processing), x-ray and particle physics,
- Programming skills: high level in C++ required.
- Language: French, English
- Location: Centre Léon Bérard, Lyon, France.
- Period: 1 year (renewable for 1 additional year) starting from end 2017/early 2018.
Contacts
Send CV by email to:
- David Sarrut David.Sarrut@creatis.insa-lyon.fr
- Etienne Testa e.testa@ipnl.in2p3.fr
- Jean Michel Létang Jean.Letang@creatis.insa-lyon.fr
- Denis Dauvergne dauvergne@lpsc.in2p3.fr
References
• Golnik, Christian, Fernando Hueso-González, Andreas Müller, Peter Dendooven, Wolfgang Enghardt, Fine Fiedler, Thomas Kormoll, et al. 2014. “Range Assessment in Particle Therapy Based on Prompt γ-Ray Timing Measurements.” Physics in Medicine and Biology 59 (18): 5399–5422. doi:10.1088/0031-9155/59/18/5399.
• Pinto, M., D. Dauvergne, N. Freud, J. Krimmer, J. M. Letang, C. Ray, F. Roellinghoff, et E. Testa. 2014. « Design Optimisation of a TOF-Based Collimated Camera Prototype for Online Hadrontherapy Monitoring ». Physics in Medicine and Biology 59 (24): 7653. doi:10.1088/0031-9155/59/24/7653.
• Min, Chul Hee, Han Rim Lee, Chan Hyeong Kim, et Se Byeong Lee. 2012. « Development of Array-Type Prompt Gamma Measurement System for in Vivo Range Verification in Proton Therapy ». Medical Physics 39 (4): 2100‑2107. doi:10.1118/1.3694098.
• Everett, D. B., Fleming, J. S., Todd, R. W., and Nightingale, J. M. (1977). Gamma-radiation imaging system based on the Compton effect. Electrical Engineers, Proceedings of the Institution of, 124(11):995–.
• Fontana, M., D. Dauvergne, J. M. Létang, J.-L. Ley, E. Testa, Compton camera study for nuclear medicine and benchmark with Anger system, submitted to Physics in Medicine and Biology
• Han, L., Rogers, W. L., Huh, S. S., and Clinthorne, N. (2008). Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging. Physics in Medicine and Biology, 53(24):7029.
• Huisman, B., J. M. Létang, E. Testa, D. Sarrut. 2016. “Accelerated Prompt Gamma estimation for clinical Proton Therapy simulations”. Physics in Medicine and Biology.
• Krimmer, J., Dauvergne, D., Létang, J. M., & Testa, É. (2017). Prompt-gamma monitoring in hadrontherapy: A review. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/j.nima.2017.07.063
• Krimmer, J., J.-L. Ley, C. Abellan, J.-P. Cachemiche, L. Caponetto, X. Chen, M. Dahoumane, et al. 2015. “Development of a Compton Camera for Medical Applications Based on Silicon Strip and Scintillation Detectors.” Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 787 (July): 98–101.
• Matsuoka, Y., Tanimori, T., Kubo, H., Takada, A., Parker, J. D., Mizumoto, T., ... Kurosawa, S. (2014). Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam.
• [Singh, 1983] Singh, M. (1983). An electronically collimated gamma camera for single photon emission computed tomography. Part I: theoretical considerations and design criteria. Medical Physics, 10(4):421–427.
• Solevi, Paola, Enrique Muñoz, Carles Solaz, Marco Trovato, Peter Dendooven, John E Gillam, Carlos Lacasta, et al. 2016. “Performance of MACACO Compton Telescope for Ion-Beam Therapy Monitoring: First Test with Proton Beams.” Physics in Medicine and Biology 61 (14). IOP Publishing: 5149–65. doi:10.1088/0031-9155/61/14/5149.
• Verburg, Joost M, and Joao Seco. 2014. “Proton Range Verification through Prompt Gamma-Ray Spectroscopy.” Physics in Medicine and Biology 59 (23): 7089–7106. doi:10.1088/0031-9155/59/23/7089.
• Dauvergne, D., Krimmer, J., & Testa, E. (2016). Procédé de détection d’une différence entre une caractéristique prédite et une caractéristique réelle d’un faisceau d’hadrons. France. Réf. ICG020479 FR (Patent application)